SEOULTECH Researchers Develop Liver-on-a-Chip Platform for Practical Chemical Toxicity Testing
Original source (eejournal)
Share Article:

Organ-on-a-chip (OOC) platforms can improve the human relevance of chemical toxicity  assessment; however, their practical application remains challenging because of limitations  in flow control, usability, and biological replication. In a new study, researchers have  developed a modular, tubing-free liver-on-a-chip (LOC) platform designed to address some  of these challenges. The platform enables controlled recirculation, highly reproducible  exposure conditions, biological replicates without pooling, stable flow control, and direct  measurement of exposure dynamics.

Among the thousands of chemicals used in daily life, toxicity information is available for only  a small fraction. Much of this information comes from high-dose animal studies, which are  costly, time-consuming, and limited by species differences. 

Organ-on-a-chip (OOC) systems use microfluidics to mimic human tissue and organ physiology,  offering a more human-relevant approach to toxicity testing. However, their application to  toxicological assessment remains challenging due to usability, flow control, and biological  replication. Complex tubing in flow-based OOC systems can further complicate their  implementation. 

To address these challenges, a research team involving Professor Ki-Tae Kim and PhD  candidate Jiyun Kang from the Department of Environmental Engineering at Seoul National  University of Science and Technology (SeoulTech), has now developed a modular liver-on-a chip (LOC) platform, designed specifically for environmental toxicological assessment. “The  use of organ-on-a-chip platformsfor environmental chemical assessment has advanced slowly,  since testing many chemicals at multiple concentrations puts different demands on the  system,” explains Prof. Kim. “Our study offers insights into how these issues can be resolved and where these systems could be useful.” Their study was made available online on August  27, 2026 and published in Volume 60, Issue 36 of Environmental Science & Technology on  September 15, 2026. 

The proposed LOC platform accommodates 12 cartridge-based chips in parallel. It features a  tubing free design with each chip consisting of an easy-to-use clamping-based sealing  mechanism. A single LOC chip consists of human liver HepG2 cultures and features  independent unidirectional recirculating flow, where the flow rate and shear stress are  determined by gear-based peristaltic pumping. Unlike static plate-based cultures, this  

recirculating flow continuously exposes cells to the circulating medium and enables  controlled, reproducible chemical exposure, better reflecting biological conditions. 

In tests, the LOC platform demonstrated stronger hepatic function compared to static plate cultures, with markedly higher expression of CYP1A2, CYP3A4, and CYP2E1 mRNA. The  researchers used the LOC platform for evaluating the hepatotoxicity of triphenyl phosphate  (TPhP), which is a common flame retardant used in household items, with known links to liver  toxicity. 

During experiments, the cartridge modules demonstrated high reproducibility and uniform  chemical distribution. In response to TPhP exposure, the platform showed changes in levels  of hepatic phenotypic markers, including urea, lactate dehydrogenase (LDH), and aspartate  aminotransferase (AST). Notably, these altered responses were observed at lower measured  concentrations compared to plate-based cultures. Furthermore, RNA sequencing of the  exposed HepG2 cells revealed changes in biological pathways associated with TPhP-induced  hepatotoxicity, including spliceosome and inflammatory signaling pathways. Overall, the  experiments showed that the platform provides biological replicates without pooling, stable  flow control and direct measurement of exposure profiles.  

“Our platform can support human toxicity assessment based on real cell exposure, enabling  next generation risk assessment,” remarks Prof. Kim. “Importantly, we measured the chemical  concentrations in the system and followed their kinetics during exposure. This means that the  toxicity observed can be tied to the concentration the cells actually experienced.” 

This work highlights how some practical challenges in applying OOCs may be addressed. The  researchers hope that continued improvements will make the technology increasingly suitable for assessing or predicting chronic effects and other long-term toxicological  outcomes. 

Reference 

Title of original paper: Modular Liver-on-a-Chip Platform for Accelerating Toxicological Applications:  A Case Study of Triphenyl Phosphate Hepatotoxicity 

Journal: Environmental Science & Technology 

DOI: https://doi.org/10.1021/acs.est.6c03280 

About the institute Seoul National University of Science and Technology  (SEOULTECH)

Seoul National University of Science and Technology, commonly known as ‘SEOULTECH,’ is a  national university located in Nowon-gu, Seoul, South Korea. Founded in April 1910, around  the time of the establishment of the Republic of Korea, SEOULTECH has grown into a large  and comprehensive university with a campus size of 504,922 m2.  

It comprises 10 undergraduate schools, 35 departments, 6 graduate schools, and has an  enrollment of approximately 14,595 students. 

Source: EE Journal