Power Corner: Littelfuse’s Martin Schulz on Direct Liquid Cooling for Commercial-Vehicle Inverters
Original source (powerelectronics)
Share Article:

Description

In this Power Corner, Dr. Martin Schulz, global principal application engineer at Littelfuse, discusses a unique traction-inverter power module that solders the power-device chips directly onto a liquid-cooled base. The innovation removes the direct-bonded copper (DBC) substrate that provides isolation through ceramic substrates and instead relies on the dielectric coolant itself, which can be either a water-glycol mixture or an oil-based coolant. 

The design targets commercial vehicles, which require 2x the operating hours of a passenger car. “You expect 8,000 hours of operation from a passenger car, but you expect 16,000 hours of operation for a truck,” says Schulz. 

To properly oversize the traction inverter for the commercial vehicle and ensure it runs throughout its service life, Schulz explains that it must be designed optimally for either efficiency or cooling [although, physically, the design challenge is the same]. “Because the one thing that kills the inverter, or any semiconductor, in the end is temperature swing,” Schulz states, as Temperature swings drive the thermomechanical stress that wears out a module.

“A few swings of 80 K are much more devastating for the module than thousands of swings of just 10 K,” Schulz states. 

A standard thermal stack involves 10 layers (Figure 1): the chip, solder layer, DBC [1st copper layer + ceramic + 2nd copper layer], solder layer, base plate, thermal interface materials (TIM), the top side of the liquid cooling system, and coolant. Schulz continues, “With direct liquid cooling, you have the chip soldered to the heat sink, period. Three layers.”

Power Corner: Littelfuse’s Martin Schulz on Direct Liquid Cooling for Commercial-Vehicle Inverters
Figure 1: Conventional module vs. direct cooling: the chip is soldered straight onto the liquid-cooled base. (Source: Littelfuse)

Coolant: Water-glycol versus oil

While the water-glycol mixture extracts the heat the best, it must stay deionized. The deionization process uses non-repairable filters that must be thrown away and replaced. Functional-safety rules add more cost as they require roughly 6 to 8 meters of tubing or expensive ceramic pumps to minimize leakage current. It makes most sense in hydrogen-fuel-cell trucks, which already need a deionized loop for the fuel cell itself.

Oil, which is also electrically non-conductive, cools less effectively, but “even if you contaminate it massively, which you can prevent with simple filters, it remains non-conductive.” Most importantly, the inverter can share the oil loop that already cools the gearbox and motors, allowing for a  “single-oil solution.” 

Testing the system

To measure how well the module sheds heat, the Littelfuse team used infrared imaging rather than individual temperature sensors. The cooling worked so well that the chips wouldn’t get hot at their rated current. 

The Littelfuse team found that a chip rated for 150 A could carry about 250 A and still stay within its 175 °C junction limit. The prototype’s four 150-A IGBTs (600-A nominal) handled 800 A within thermal limits, using oil. 

In simulation, under the same operating conditions, a conventional liquid-cooled power module reached a junction temperature of ~150 °C. The direct-cooled module reached ~60 °C with oil and ~55 °C with a water-glycol mixture. For context, a conventional 150-A chip is typically rated at a case temperature of 80 °C and a junction temperature of 150 °C.

Power Corner: Littelfuse’s Martin Schulz on Direct Liquid Cooling for Commercial-Vehicle Inverters
Figure 2: Power-cycling lifetime vs. temperature swing. Direct cooling moves the module from about 100,000 cycles to tens of millions. (Source: Littelfuse)

Lifetime extrapolation

In order to estimate lifetime, Littelfuse used the profile of a truck driving on a real truck route through Germany. They combined this with their own lab measurements (losses, forward characteristics, heat development) to simulate how the inverter’s chips would heat up and cool down along the route.

The resulting temperature swings drive the wear. A few large swings do far more damage than many small ones, and most of them come from hill climbs, when a fully loaded 40-ton truck pulls hard after cooling down in a valley. Assigning a damage factor to each cycle, Littelfuse found that the direct-cooled design took 97% less damage per run of the route than a conventional module.

“That means to do the same 100% damage, we would need to pass through the same load profile 33x. And that’s the factor we got in prolonging lifetime, about 30x,” says Schulz. According to Schulz, on the power-cycling curve, the module moves from about 100,000 cycles (typical) to tens of millions.

Transcript

AS: Welcome, everyone, to Power Corner. I’m your host, Aalyia Shaukat, Editor-in-Chief of Power Electronics News. Today, we’re speaking with Dr. Martin Schulz, Global Principal Application Engineer at Littelfuse. Hey, Martin, how are you doing today?

MS: I’m fine. Thanks for having me.

AS: Well, thanks for being here. It’s a very exciting time. I know there’s some recent news: you’ve just marked 5 consecutive years presenting at PCIM, and you’ve had six papers over that time. The topics range from thyristors and GTOs to battery disconnect switches to, of course, the direct liquid cooling system that we’re about to talk about. But before we get into that, looking back at your five years presenting, what are some of the common problems that you keep returning to?

MS: Well, actually, I’ve been with the PCIM conference for about 20 years now. And during that time, the topics have focused on the same thing, because the common enemy in power electronics is the same: it’s heat. 

To eliminate heat, the two ways are improved cooling, better cooling systems, or improvements in efficiency. And it all turns out to increase power density. So that’s the big three. Systems are expected to lose less energy and be more efficient. Being more efficient allows building smaller pieces, and even if you build smaller pieces with more efficient semiconductors, the power density loss remains the same, which brings it down to cooling again. 

So that’s a Penrose triangle you tend to run in.

AS: Power density, efficiency, and cooling, right?

MS: That’s literally it. Among others, there’s topology and application-specific questions, but they all somehow come back to efficiency, power density, and cooling.

AS: Well, speaking of cooling, we’re going to dive into the direct liquid cooling system, a recent innovation. But before we get into that, I think it would be helpful to discuss the cooling requirements for inverters in commercial vehicles. How do they change compared to passenger vehicles?

MS: Actually, technically and physically, they’re the same. The challenge remaining is that a typical passenger car is designed to operate for only 8,000 hours. Looking at a year having more than 8,000 hours, how’s that enough? 

Well, a passenger car runs 1 hour a day, so 8,000 operating hours turn into 8,000 days in operation, which is 20 years and perfectly fine. A truck is supposed to run 10 hours, 12 hours every day, which makes it 4,000 hours a year, but it is expected to do 15 years of operation, at least with the first owner, and then be sold into the secondhand market and do another 10 years. 

So, in comparison, you expect 8,000 hours of operation from a passenger car, but you expect 16,000 hours of operation for a truck. And if you take the same inverter with the same load profile and the same lifetime expectation, and you know it’s good enough to operate 8,000 hours with a certain margin, being potentially good enough for 10,000 hours, after two years in a truck, it’s gone. 

That means you have to oversize the inverter in the truck accordingly, and it comes down to power density, cooling, and temperature, because the one thing that kills the inverter in the end, or any semiconductor, is temperature swing. So to extend the lifetime, you need to reduce temperature swing. Two options: higher efficiency or improved cooling. Physically, they’re the same.

AS: But you’ve got, of course, the lifetime requirements, so you’re pushed toward the power density and cooling requirements. Can you walk me through the typical thermal stack in the traction inverter module? Where’s the bottleneck? Could it be the ceramic itself, the interface material, the number of layers? What is it?

MS: If you look at a classical approach, you have a power module with a plain base plate. You put a thermally conductive thermal interface material onto this base plate and then mount it to a liquid cooling system. 

Internally, the module consists of this base plate. On top, you have a so-called DCB, which is a direct copper bonding substrate that consists of a ceramic sandwiched between two copper layers. 

The lower side of the copper is connected to the base plate, and the top side is what carries the chip. So the full stack consists of the chip, solder material, the first copper layer, ceramic, copper layer again, solder layer again, base plate, thermal interface material [TIM], the top side of the liquid cooling system, and then you get down to the liquid, which means there are 10 layers involved.

AS: Wow. Let’s talk about the direct liquid cooling technology you worked on. How does it remove some of those bottlenecks?

MS: With direct liquid cooling, you have the chip soldered to the heat sink, period. Three layers. 

Every layer imposes a thermal resistance, and the task of this ceramic is to isolate the chip from the heat sink, because in a typical approach, you want the heat sink to not be electrically active. 

And that ceramic is a good electrical isolator. The trouble is that materials that are good at electrical isolation are also good at thermal isolation. So eliminating this layer improves the thermal transfer path massively, but it shifts the isolation requirement to the liquid cooling. 

So now the block surrounding the cooling is electrically active, and you need to prevent short circuits, cross currents, or a person touching it. And the one way you can do so is to put electrically isolating cooling liquid in it. 

So the idea remains the same: you need the electrical part isolated from touchable areas, but the way of doing it is different. That breaks the dogma of classical approaches, but massively improves the thermal transfer in turn.

AS: So the ceramic is gone, and you maintain isolation with the coolant, essentially.

MS: Correct.

AS: And I understand that you use a low-conductivity coolant, and I believe it was a deionized water-glycol mixture, right? Does its conductivity drift over the vehicle’s service life, and is there a maintenance or replacement interval for this kind of coolant?

MS: This system coincidentally has some drawbacks and some benefits. One of the drawbacks is that the distances you need to bridge are so small that a deionized water-glycol mixture works on paper. 

However, you need to account for contamination, and once the electrical conductivity of the water reaches a certain limit, you reach points that are no longer tolerable. To keep deionized water deionized, you need filter units that are non-restorable and need maintenance, but the maintenance is not regenerating the filter. It’s taking it out, throwing it away, and building a new one in. So that’s a lot of downtime and replacement cost, and not beneficial. 

However, the vehicle already has a second cooling system for the mechanical parts. The gearbox and machines are cooled using oil. Oil, by design, is electrically non-conductive, and even if you contaminate it massively, which you can prevent with simple filters, it remains non-conductive. The drawback is that oil is less good at extracting heat than water. 

The beauty of combining those two approaches now is that we improve the thermal resistance in the power semiconductor, so we can tolerate oil as a coolant and still have the cooling effect we need. 

And we get to something that the truck industry considers a “single-oil solution.” So we eliminate a complete cooling system with pumps, tubes, and radiators for a second material. It’s all gone. You can stay with one cooling system, and that reduces system complexity, therefore system cost, and is a secondary benefit of having this non-isolated approach.

AS: And it’s still much better than the conventional approach.

MS: I’d say it’s still better. Of course, it would be beautiful to have it cooled with a water-glycol mixture, but that’s not an option. However, the beauty is getting the same performance or slightly better in a much less complex system.

AS: Okay, that makes sense. I was wondering, how do you monitor the insulation quality?

MS: Well, that’s pretty easy. You can install what is called, in the AC world, RCDs, residual current detectors. 

So you can check whether there is a current flowing through the liquid into places where it doesn’t belong and, very similar to these RCD switches, get a message out that something’s wrong. 

However, using oil, this is not to be expected, because oil is so high in resistivity, or so low in conductivity, that there’s very little risk. If your oil is contaminated to a degree where it starts to be electrically conductive, you would have much more severe problems than that.

AS: The best option is the water-glycol mixture, but that requires the filters.

MS: From thermal aspects, yes. From economic aspects, no.

AS: And the option that requires the deionized loop, does that need a separate heat exchanger?

MS: Deionized liquid is potentially found in a truck today because the truck is driven by a hydrogen fuel cell, and this hydrogen fuel cell needs deionized cooling. If that remains, then you can try to go along with the deionized coolant. 

However, and that’s the major part, there’s a topic in the automotive and also the trucking industry which is called functional safety. If you have a power system that demands something like a coolant flow of 20 or 30 liters per minute–which is pretty low compared to a combustion engine–you need a certain tube diameter to transfer the liquid to the power electronics. 

And accounting for a certain contamination, which by definition you have to, and seeing the diameter of the tube, you can consider the liquid becoming a conductor. Even if it’s a very bad conductor, standards demand that, to keep functional safety and safety requirements, you need a certain amount of resistance to protect people. And to get to this resistance, we figured out you need six to eight meters of tube. 

That’s something you try not to tolerate, or you would have to keep the whole system completely isolated, which means the pump that’s moving the liquid has to consist of zero metal parts. So you turn to ceramic pumps, which are available, but guess what? They’re hell expensive. 

So getting rid of this in an all-electric vehicle, battery-driven, not fuel-cell-driven, where you don’t need deionized water but potentially also have the battery flooded with a synthetic oil for coolant, you can now remain with a single oil cooling system. One pump, one radiator, one monitoring system, and it’s all captured.

AS: Okay, got you. So maybe we can shift to the thermal testing, because I know your paper has several tests, and we’ll walk through them. But we’ll start off with the thermal testing. Could you discuss the laboratory setup for the thermal measurements on the direct liquid cooling system, and the results there?

MS: Yeah, for sure. For the thermal testing, the most robust data is captured by infrared imaging [IR], because everything else, like putting a spot sensor or a thermocouple on it, only gets you one bit of information, while infrared imaging lets you see all the chip’s temperature development and the temperature gradients. You don’t only get temperature information; you also get information about temperature spreading, how the heat develops, and this is far more accurate for steady-state observation. 

So what you do is take a raw component with no isolation on top, which is typically some sort of optically transparent soft gel. But optically transparent doesn’t mean it’s transparent to infrared. So this gel would block the infrared, and you cannot see the heat developing. 

So you need a module or a component that doesn’t feature this gel on top, and you need to blacken it, which is a consequence of the so-called emission factor. A shiny surface has a different emission factor than a non-shiny one. 

So you put a certain spray-coated paint on top of the power semiconductor, then you apply current, which leads to losses. The losses heat up the semiconductor, and then your infrared camera can capture an image. This image allows you to conclude where heat is developing, where it is going to, and what absolute temperature reading you get. 

An infrared image may be something like 640 by 320 dots, so that’s a lot of information. You don’t get a single bit of information from one sensor; you get hundreds and hundreds of pixels per chip where you can check the temperature. 

And what we found is that the heat in this setup is extracted so efficiently that, within the expected and rated values for the chip, we couldn’t get it hot. Assume we have a chip with a 150-A rated current, and the current rating is only reasonable information if it comes combined with a temperature correlation.

So for a classical approach, you would say, okay, you can drive 150 A with a case temperature below the chip of 80oC and a chip temperature of 150oC. In our case, we have the liquid cooling as the case temperature, and the chip is only something like 2 mm of copper away from this cooling system. 

And the thermal conductivity is so high that, if we stick to the specification, we’d say, “Okay, the chip is rated 150 A, then it doesn’t get hot.” 

But the chip is also rated for something like a 175oC allowed operating junction temperature, and then we no longer apply 150 A, but 250 A. So that’s the jump in power density you can get from this more aggressive cooling approach. 

Our test specimen was equipped with four IGBTs in parallel, 150 A rated each, which means 600 A. But we can easily take 800 A from it without exceeding the thermal limits.

AS: This is using the deionized water-glycol mixture for the coolant, right?

MS: No, that happens with oil. 

With water, it gets a little better still, but we’re not talking about a huge difference. We did a comparison to a classical approach: a power module on a closed heat sink, liquid-cooled. 

We reached a chip temperature of about 150oC in the simulation, and with the same parameters using oil, the chip temperature only reached something close to 60oC, and with water, it got to 55oC.

AS: So, would you say it performed better in the benchtop test than it did in simulation?

MS: No, no, no. The simulation was fed with the data we gathered from our benchmark testing. For a simulation without verification by model, the confidence level is 50%. Maybe true, maybe not. 

But we took the data from our measurements as a foundation for the simulation and transferred that simulation to the classical approach as well, and then it showed that, hey, we can shave off a temperature swing of about 80 K. And just to give you an impression, we consider that 20 K of added temperature halves the lifetime.

AS: Wow. Okay. So let’s shift to the double-pulse test fixture, so we can talk about electrical performance. How was the module integrated with the gate driver PCB for the double-pulse test?

MS: For the double-pulse test in the lab, we typically use lab equipment and have gate drivers that offer all the isolation and driving features, and then the semiconductor module is integrated into a DC link structure in the shape of a half-bridge, so you have a high-side switch and a low-side switch. 

The high-side switch just provides the diode, the freewheeling diode for an inductive load, and the low-side switch is the device under test. And there’s no real integration. We don’t put a PCB on top; we attach a laboratory-setup gate driver using coaxial wire to keep inductances in the gate path as low as possible, and then we apply a pulse. 

The pulse applies a voltage to the inductive load, which leads to a linear ramp-up in current, and this way, you can observe what your power semiconductor does at every voltage you want, every current you want, and, by heating it up with an external source, even at any temperature you want. That’s why a double-pulse test really gets you a very holistic impression of how your semiconductor behaves.

AS: And what were the results?

MS: The result was that, as expected from this prototype, the device itself still suffers from an inconveniently high internal stray inductance, period. That’s it. But that comes from the quick-and-dirty approach to building those prototypes. However, it’s not unmanageable. We managed to easily squeeze 800 A when applying 800 V, and that’s exactly the range that’s currently asked for in trucks. And we’re looking forward to having a first inverter built and tested, actually, within the next few weeks.

AS: Exciting. Now, correct me if I’m wrong in saying this. From what I understand, you have one test fixture that uses a non-isolated gate driver IC on a single switch, but when you move to a full inverter leg, the cold plates themselves are live. So how does this affect where the gate drivers go and how you lay out the board around the cooler?

MS: No, the misconception you stepped into, I think, is that there is no cooler. The module is the cooler. So the beauty of it is that you no longer need a very thick, stiff aluminum case or aluminum carrier to put all the modules onto. You could simply mount it onto something like a 10-mm PCB plate, keep it isolated, and then, on top, you can work on it, because it has the same connections for any gate drive structure you want. 

It’s difficult to share a picture now; it’s in the paper. We built a small PCB that contains the gate drive unit, and that’s a non-thrilling approach. It’s business as usual. You build a gate driver, you solder it to the module, and you check whether it’s working, and it did, and here we go. So that’s not different from any other approach you can ask for as of today.

AS: Got you. Well, I was wondering how you deal with common-mode current through the coolant and the hoses once you build the half-bridge.

MS: Yeah, that’s a very difficult question to answer, because common-mode typically flows through the isolation into a grounded heat sink, which we don’t have. So I cannot claim there is no common-mode current, but the typical approach is that you put Y-capacitors at the output of the inverter, and that’s done in the design we’ll see being tested soon. 

But for sure, because the capacitances are much smaller, because the distances grow, the common-mode problem should be much smaller than in a classical approach, where your DBC with a ceramic inside forms a plated capacitor. And that we don’t have. We don’t have a second area that works as a capacitive coupling. From that perspective, I’d expect common-mode currents to be a much smaller problem than today.

AS: Thank you. So, I understand we’re going to move on to the simulated drivetrain testing. You did the simulated drivetrain testing using real mission profile data. Can you describe a little bit more about this test in particular?

MS: Yeah, so we now need to more carefully distinguish between test and simulation. What we got was a driving profile that was recorded on a truck going through Germany. This is an awesome amount of data and a treasure trove of information for simulations. 

With the measurements we did, the losses we measured, the forward characteristics, and the heat development, we took this load profile and simulated how the inverter would behave, how the temperature in the drives and in the devices would rise and drop with this load profile. And that also leads to the lifetime question later. 

With this load profile, you can check how the temperature swing in the devices develops. And the temperature swing is what superimposes the thermomechanical stress. 

So, coming back to the comparison with the classical approach, from this mission profile, we derived a current profile. From the current profile, you can derive losses, and with the losses, you can derive a temperature profile. 

And then, looking at this temperature profile, what really bothers us is the high temperature swings that occur. The trouble is that a few high temperature swings do much more damage than hundreds of low temperature swings, because the correlation is logarithmic in nature. 

So a few swings of 80 K are much more devastating for the module than thousands of swings of just 10 K. 

A truck doing constant speed on flat ground will not see temperature swings, because it goes at constant speed, constant torque, delivering constant current, constant temperature. Here we go. But once your truck starts overtaking slower vehicles, going uphill, potentially going downhill and recovering energy, going stop-and-go through cities, you have those temperature swings. 

\It turns out that in cities, the acceleration is so low and the speeds are so low that the temperature swing isn’t really high. Where the temperature swing goes high is when you start climbing hills. With a fully loaded truck, you come through a valley, the IGBTs or the semiconductors cool down, and then the driver wants to keep the speed going uphill. 

And now suddenly, you need to move 40 tons uphill, and that really gets you high torque demand, high current demand, and therefore it leads to high temperature swings. 

But how often does it happen? It doesn’t happen too often. If you’re crossing the Rocky Mountains or the European Alps, then you’re in trouble. You really are, because that adds a lot of high-temperature cycles. 

And you can now calculate a damage factor for each cycle. We did this for the reference with the classical approach, including DBC and the higher temperature swing. 

We figured out that running through this load profile, assuming that this load profile poses 100% damage for one module in the classical approach, doesn’t mean the module is dead afterward. It just means that, per unit, this damage is considered 100%. 

How much less would it be with the lower temperature swing in our design? And we figured we got a reduction of 97%.

AS: That’s very significant.

MS: That means to do the same 100% damage, we would need to pass through the same load profile 33x. And that’s the factor we got in prolonging lifetime, about 30.

AS: So how does this improvement look on the power cycling curve?

MS: It looks ridiculous. On the power cycling curve, because of this logarithmic effect, you could say that reducing the temperature swing by 20 K doubles the lifetime, or doubles the number of cycles. 

We got a reduction of 80 K, so 2x for 20 K, 4x for 40 K, 8x for 80 K. So we grow from a regime where the classical approach survives 100,000 cycles into a regime where we get double-digit millions of cycles. 

Hopefully, the inverter will soon be submitted to a hardware-in-the-loop [HiL] test. It’s a system where you can impose this load profile onto the inverter without being on the street. That’s pretty convenient, because it’s easier to observe, to monitor, and to maintain in case something goes wrong. 

And we hope to see the data that’s gathered in this testing. If it’s successful, then the plan is to integrate it into an existing vehicle and at least run it on test tracks. It’s difficult to get homologation for a truck to run on public streets, but it’s easier to put the hardware into a truck that is then operated on a test track.

AS: Just out of curiosity, are you going to test with the same load profile, or are you exploring other load profiles for the real testing?

MS: This 700-km load profile, north to south and south to north through Germany, includes literally all the bad things you can ask for. We’re talking about the Kassel Hills. 

Kassel is one place in Germany where you’ve got slopes up and down in the area of 8% to 12% of slope for kilometers of duration. So that’s one of the worst-case scenario places in Germany. But also in the southern region, you have quite some steep hills to climb. So this load profile is potentially not 100% worst-case, but it’s pretty severe. If we manage that, we’ll be fine.

AS: I wanted to ask, can you use silicon carbide MOSFETs or GaN HEMTs in this setup? Why did you start with IGBTs in particular?

MS: We started with IGBTs for pragmatic reasons. One, our lead customer asked for it. That’s a major point. And the other thing was, it’s available. 

For our technology, we need a chip that we can not only mount onto a heat sink, but we also need to be able to mount copper sheets on the front side for our proprietary clip-and-tab interconnection. 

And that’s something that’s not commonly available: chips that you can solder parts onto on the top side. They’re optimized for bonding aluminum wires, but they’re not optimized for soldering. 

And this particular IGBT was available; that’s why it was beneficial for us. But the technology in general is open to any power semiconductor. I see IGBTs, silicon MOSFETs, and silicon carbide MOSFETs coming. 

With GaN HEMTs, or with GaN parts, it will become challenging, particularly for two reasons. Our customers are asking for voltages higher than 1,200 V, which is not currently available in GaN. And the other thing is that GaN switches so fast that you need to get the stray inductances down much more than you need to with silicon carbide or silicon. So simply replacing the devices we have with GaN wouldn’t work. 

But we’re currently working on other direct liquid cooling structures that allow us to reduce stray inductance and then to make use of silicon carbide for sure. But for the time being, I don’t see GaN happening. It would be nice to see, but I don’t see a driving force to put it in there right now.

AS: I see. Understood. Beyond single switches and half-bridge phase legs, are there any other topologies that this direct liquid cooling could support?

MS: Yeah. The good thing in power electronics is that if you have a single switch, you can build anything you want, but the connection will introduce stray inductance. So the second building block would most likely be a half-bridge, which would allow you to build a six-pack using three half-bridges. 

The trouble with direct liquid cooling is that if you have a half-bridge, you have one inlet and one outlet. So if you build a six-pack, you have six tubes to connect. If I could build a six-pack in one block, I’d still have one inlet and one outlet. Bigger tubes, though, but it’s more convenient to handle two tubes instead of six. 

So the question is not what topology we can build. We can build any of them. That’s not the issue. The tricky thing will be what combination of topologies or building bricks can be reasonably integrated in a single housing to allow single tube in, single tube out. 

And the classic ones are six-packs, six-packs with brake choppers, and 12-packs to drive switched reluctance machines. Switched reluctance machines need a slightly different topology. They do not need three half-bridges; they need three sets of high- and low-side switches. So choppers.That means you don’t need three half-bridges; you need six choppers. 

But this too is possible: as we found a way to integrate a half-bridge, building a high-side and a low-side chopper is just a matter of placing chips. So the technology itself is not limiting the topologies we can build.

AS: Understood. Well, then I suppose this does lead to applications. Do you see any applications beyond traction inverters that this could find traction in?

MS: Pun intended. Yeah, of course. The trucks came to us coincidentally. But the technology is a good fit for any high-power application where liquid cooling is inherently part of the design. 

That is, for example, any high-power equipment where metal melting is done by inductive heating. Electrolysis would be a good point to start. The power density grows so big instantly that we’re not talking about small devices like general-purpose drives in the 100-kilowatt regime. That would be literally ridiculously oversized. 

Even if we scale it down to a single set of chips, building it for less than 200 or 300 A is simply not a feasible option. So we’re talking about higher power requirements, and then the metal industry comes in: welding, metal melting, metal treatment in general, electrolysis, wind power, high-power solar. And one intriguing application would be what’s currently growing: solid-state transformers. Because guess what? They’re cooled using oil.

AS: Well, then that’s an obvious application, isn’t it? And it’s certainly a growing one for silicon carbide.

MS: Yeah, for sure. And one curious discussion I had with a customer is that potentially we’re not going for wide-bandgap material, but for the anachronistic things: putting bipolar diodes and thyristors into it, because there are soft starters for megawatt motors that need classical phase-controlled thyristors. And making those smaller may also become an option. 

People often think, “Hey, you work on IGBTs, why not go for silicon carbide or GaN?” The other question is, why not consider GTOs, thyristors, IGCTs, or whatever other so-called ancient technology still has a good use case? As I said, the cooling itself doesn’t care what chip you put onto it.

AS: That’s a great way to sum it up. That was my last question, Martin. Thank you so much for your time.

Tags: Liquid Cooling, Power Management, Power Module, Thermal, Traction Inverter